GCAN-PLC-400/510/511 —— with CAN bus communication capability
GCAN-PLC module is composed of a programmable control module (GCAN-PLC-400/510/511) and several I/O modules(GC-1008/2008/…). The control module has a variety of fieldbus communication interfaces that users can use to connect to the corresponding network and communicate with other devices.
Brand:GCAN
Model:GCAN-PLC-400/510/511
Feature:
1.Programming software: OpenPCS;
2.Support Ethernet, RS232/485, CAN Bus interface;
3.Support CANopen protocol master/slave station;
4.Support Modbus RTU/TCP protocol master/slave station;
5.Support 5 language of IEC61131-3 standard;
6.Support digital & analog and special expansion IO module;
7.Max 32 expandable IO modules with extra power modules;
8.Configuration mode: automatic configuration;
9.Provide customizable services (programming/logo/software……)
Model |
Characteristic |
Communication bus |
CPU frequency |
Program storage |
Data storage |
GCAN-PLC-400 |
168M |
16M |
512K |
1*CAN+1*Ethernet+1*RS232(or RS485) |
GCAN-PLC-510 |
400M |
32M |
16M |
1*CAN+1*Ethernet+1*RS232(or RS485) |
GCNA-PLC-511 |
400M |
32M |
16M |
2*CAN+1*Ethernet+1*RS232+1*RS485 |
3 kinds if interface
CAN, Ethernet, RS232/485, Follow ISO 11898, support CANopen/ Modbus RTU/ Modsbus TCP, can be used as master or slave station
5 programming language
Support SFC (Sequential function chart), LD (Ladder diagram), FBD (Function block), ST(Strutured text), IL (Instruction list)
After-sales service
7 x24 hours every week after sales technical support with our professional engineers to solve problems
IO freely expand
Plenty of IO modules optional including digital & analog IO modules and some other special modules. One main control module with max 32 IO modules (32*8=256 channels)
Free programming software
Support OpenPCS software, follow IEC 61131-3, the software is free with GCAN-PLC
Without specialized downloader
GCAN-PLC can use common micro usb to complete debugging and downloading
GCAN-PLC can be programmed in five programming languages that comply with the IEC61131-3 standard, which makes the PLC program portable and reusable. IEC61131-3 also allows multiple programming languages to be used in the same PLC, allows program developers to select the appropriate programming language for each specific task, and allows different software modules to use different programming languages in the same control program prepared by.
“GCAN Internet” industrial Internet platform is a new industrial Internet platform that integrates software services, attachment services and other services. Our company can design a set of digital monitoring and control that meets the user’s own needs through the platform. System, users can also use the platform to remotely access field devices to achieve high-end functions such as status monitoring, remote control, fault diagnosis, and unified management of field devices
GCAN-PLC can be programmed with German OpenPCS software. OpenPCS is a powerful PLC software programming tool. Users can select different language editing subroutines in the same project. Function modules, etc.
GCAN will provide users with commonly used function examples such as basic input and output, basic RS232/RS485/Ethernet/CAN communication, CANopen protocol communication, Modbu protocol communication, etc., which can be used by users. Quickly develop a PLC application that suits you, saving development time and reducing development costs.
GCAN-IO-8000/8100 —— with CANopen & Modbus communication protocol
Performance |
CANopen adapter (GCAN-IO-8000) |
Modbus adapter (GCAN-IO-8100) |
Node number |
1~127 |
1~247 |
Baud rate |
10Kbps~1000Kbps |
600bps~115200bps |
Power input |
24V DC (18~36V) |
Insert I/O module number |
32 pieces (at most 32*8 IO point) |
Dimension |
100mm*69mm*48mm |
Working temperature, humdidness |
-40℃~+85℃, 0~90%RH, without condensation |
IP grade |
IP20 |
Module feature |
- Standard CANopen slave station
- Support 4 TPDO, 4 RPDO
- Support 1 SDO, 1 emergency object, 1 node error control object
- Start to perdefine connection, suppor parameters store
- PDO mode supports synchronization, looping, event-driven, polling
- Configuration mode is automatic configuration
- CAN interface: one open 4 terminal
- Input current, 70mA+ ( total GC-bus current), maximum 2.5A
- Starting current: about 2.5 times continuous current
- Power contacts: maximum 24V DC/maximum 10A
- Electrical isolation: 1500 Vrms
|
- Support standard Modbus protocol, a standard Modus slave station
- Support Modbus function code:01, 02, 03, 04, 05, 06, 15, 16
- Support CRC validation
- Support Modbus TCP, Modbus RTU communication (corresponding to two kinds of style)
- RS485 interface adopts standard two-wires system
- Serial interface baud rate supports 600bps~115200bps, configured by serial interface
- The maximum number of bus terminals module is 64
- Configuration mode is automatic configuration, expandedfreely
- Ethernet interface supports static or dynamic IP acquisition
- Ethernet interface supports heartbeat and timeout disconnection
- Ethernetwork interface is fixed, target IP and target interface can be set
- Automatic restoration of connection resources after the Ethernet interface is disconnected,and reliable establishment of TCP connections
- Ethernet interface is compatible with the SOCKET working mode (TCP Server, TCP Client,UDP, etc.). The upper computer communication software complies with the standard SOCKET rules.
- Input current, 70mA+ (total GC-bus current), maximum 4500mA
- Starting current: about 2.5 times continuous current
- Power contacts: maximum 24V DC/maximum 10A
- Electrical isolation: 1000 Vrms (power contact/bus coupled powervoltage)
- Standard DIN rail,designed for industrial design
-
|
GC-1008~8012 —— with digital & analog and special IO modules
IO Module Selection Table |
I/O |
Type |
Characteristic |
Signal |
Channel |
Digital input |
GC-1008 |
Digital input (PNP) |
24V DC |
8-channel |
GC-1018 |
Digital input (NPN) |
24V DC |
8-channel |
GC-1502 |
Counter(200kHz max) |
– |
2-channel |
Digital output |
GC-2008 |
Digital output (PNP) |
24V DC |
8-channel |
GC-2018 |
Digital output (NPN) |
24V DC |
8-channel |
GC-2204 |
Relay output |
– |
4-channel |
GC-2302 |
PWM (20Hz~200kHz) |
– |
2-channel |
Analog input |
GC-3604 |
Voltage input, 16 bits |
-5~+5V |
4-channel |
GC-3624 |
Voltage input, 16 bits |
-10V~+10V |
4-channel |
GC-3644 |
Current input, 16 bits |
0-20mA |
4-channel |
GC-3654 |
Current input, 16 bits |
4-20mA |
4-channel |
GC-3664 |
Voltage input, 16 bits |
0~+5V |
4-channel |
GC-3674 |
Voltage input, 16 bits |
0~+10V |
4-channel |
GC-3804 |
2-wire PT100, 16 bits |
Thermal resistance |
4-channel |
GC-3814 |
2-wire PT1000, 16 bits |
Thermal resistance |
4-channel |
GC-3822 |
3-wire PT100, 16 bits |
Thermal resistance |
2-channel |
GC-3832 |
3-wire PT1000, 16 bits |
Thermal resistance |
2-channel |
GC-3844 |
K type thermocouple |
Thermocouple |
4-channel |
GC-3854 |
S type thermocouple |
Thermocouple |
4-channel |
GC-3864 |
T type thermocouple |
Thermocouple |
4-channel |
GC-3874 |
J type thermocouple |
Thermocouple |
4-channel |
Analog output |
GC-4602 |
Voltage output, 16 bits |
-5V~+5V |
2-channel |
GC-4622 |
Voltage output, 16 bits |
-10V~+10V |
2-channel |
GC-4642 |
Current output, 16 bits |
0-20mA |
2-channel |
GC-4652 |
Current output, 16 bits |
4-20mA |
2-channel |
GC-4662 |
Voltage output, 16 bits |
0~5V |
2-channel |
GC-4672 |
Voltage output, 16 bits |
0~10V |
2-channel |
GC-4674 |
Voltage output, 12 bits |
0~10V |
4-channel |
Special module |
GC-6101 |
RS232/RS485 extension |
– |
– |
GC-6201 |
GPRS extension |
– |
– |
GC-6501 |
WiFi extension |
– |
– |
GC-8012 |
Power extension |
– |
– |