Product Description

Main control module

Home/PLC & IO Coupler Series/Main control module

Brand:GCAN
Model:GCAN-PLC-400/510/511
Feature:
1.Programming software: OpenPCS;
2.Support Ethernet, RS232/485, CAN Bus interface;
3.Support CANopen protocol master/slave station;
4.Support Modbus RTU/TCP protocol master/slave station;
5.Support 5 language of IEC61131-3 standard;
6.Support digital & analog and special expansion IO module;
7.Max 32 expandable IO modules with extra power modules;
8.Configuration mode: automatic configuration;
9.Provide customizable services (programming/logo/software……)

GCAN-PLC-400/510/511 —— with CAN bus communication capability

GCAN-PLC module is composed of a programmable control module (GCAN-PLC-400/510/511) and several I/O modules(GC-1008/2008/…). The control module has a variety of fieldbus communication interfaces that users can use to connect to the corresponding network and communicate with other devices.

 

Model Characteristic Communication bus
CPU frequency Program storage Data storage
GCAN-PLC-400 168M 16M 512K 1*CAN+1*Ethernet+1*RS232(or RS485)
GCAN-PLC-510 400M 32M 16M 1*CAN+1*Ethernet+1*RS232(or RS485)
GCNA-PLC-511 400M 32M 16M 2*CAN+1*Ethernet+1*RS232+1*RS485

3 kinds if interface

CAN, Ethernet, RS232/485, Follow ISO 11898, support CANopen/ Modbus RTU/ Modsbus TCP, can be used as master or slave station

5 programming language

Support SFC (Sequential function chart), LD (Ladder diagram), FBD (Function block), ST(Strutured text), IL (Instruction list)

After-sales service

7 x24 hours every week after sales technical support with our professional engineers to solve problems

IO freely expand

Plenty of IO modules optional including digital & analog IO modules and some other special modules. One main control module with max 32 IO modules (32*8=256 channels)

Free programming software

Support OpenPCS software, follow IEC 61131-3, the software is free with GCAN-PLC

Without specialized downloader

GCAN-PLC can use common micro usb to complete debugging and downloading

GCAN-PLC can be programmed in five programming languages that comply with the IEC61131-3 standard, which makes the PLC program portable and reusable. IEC61131-3 also allows multiple programming languages to be used in the same PLC, allows program developers to select the appropriate programming language for each specific task, and allows different software modules to use different programming languages in the same control program prepared by.

“GCAN Internet” industrial Internet platform is a new industrial Internet platform that integrates software services, attachment services and other services. Our company can design a set of digital monitoring and control that meets the user’s own needs through the platform. System, users can also use the platform to remotely access field devices to achieve high-end functions such as status monitoring, remote control, fault diagnosis, and unified management of field devices

GCAN-PLC can be programmed with German OpenPCS software. OpenPCS is a powerful PLC software programming tool.  Users can select different language editing subroutines in the same project. Function modules, etc.

GCAN will provide users with commonly used function examples such as basic input and output, basic RS232/RS485/Ethernet/CAN communication, CANopen protocol communication, Modbu protocol communication, etc., which can be used by users. Quickly develop a PLC application that suits you, saving development time and reducing development costs.

GCAN-IO-8000/8100 —— with CANopen & Modbus communication protocol

 

Performance CANopen adapter (GCAN-IO-8000) Modbus adapter (GCAN-IO-8100)
Node number 1~127 1~247
Baud rate 10Kbps~1000Kbps 600bps~115200bps
Power input 24V DC (18~36V)
Insert I/O module number 32 pieces (at most 32*8 IO point)
Dimension 100mm*69mm*48mm
Working temperature, humdidness -40℃~+85℃, 0~90%RH, without condensation
IP grade IP20
Module feature
  • Standard CANopen slave station
  • Support 4 TPDO, 4 RPDO
  • Support 1 SDO, 1 emergency object, 1 node error control object
  • Start to perdefine connection, suppor parameters store
  • PDO mode supports synchronization, looping, event-driven, polling
  •  Configuration mode is automatic configuration
  • CAN interface: one open 4 terminal
  • Input current, 70mA+ ( total GC-bus current), maximum 2.5A
  • Starting current: about 2.5 times continuous current
  • Power contacts: maximum 24V DC/maximum 10A
  • Electrical isolation: 1500 Vrms
  • Support standard Modbus protocol, a standard Modus slave station
  • Support Modbus function code:01, 02, 03, 04, 05, 06, 15, 16
  • Support CRC validation
  • Support Modbus TCP, Modbus RTU communication (corresponding to two kinds of style)
  • RS485 interface adopts standard two-wires system
  • Serial interface baud rate supports 600bps~115200bps, configured by serial interface
  • The maximum number of bus terminals module is 64
  • Configuration mode is automatic configuration, expandedfreely
  • Ethernet interface supports static or dynamic IP acquisition
  • Ethernet interface supports heartbeat and timeout disconnection
  • Ethernetwork interface is fixed, target IP and target interface can be set
  • Automatic restoration of connection resources after the Ethernet interface is disconnected,and reliable establishment of TCP connections
  • Ethernet interface is compatible with the SOCKET working mode (TCP Server, TCP Client,UDP, etc.). The upper computer communication software complies with the standard SOCKET rules.
  • Input current, 70mA+ (total GC-bus current), maximum 4500mA
  • Starting current: about 2.5 times continuous current
  • Power contacts: maximum 24V DC/maximum 10A
  • Electrical isolation: 1000 Vrms (power contact/bus coupled powervoltage)
  • Standard DIN rail,designed for industrial design

 

GC-1008~8012 —— with digital & analog and special IO modules

 

IO Module Selection Table
I/O Type Characteristic Signal Channel
Digital input GC-1008 Digital input (PNP) 24V DC 8-channel
GC-1018 Digital input (NPN) 24V DC 8-channel
GC-1502 Counter(200kHz max) 2-channel
Digital output GC-2008 Digital output (PNP) 24V DC 8-channel
GC-2018 Digital output (NPN) 24V DC 8-channel
GC-2204 Relay output 4-channel
GC-2302 PWM (20Hz~200kHz) 2-channel
Analog input GC-3604 Voltage input, 16 bits -5~+5V 4-channel
GC-3624 Voltage input, 16 bits -10V~+10V 4-channel
GC-3644 Current input, 16 bits 0-20mA 4-channel
GC-3654 Current input, 16 bits 4-20mA 4-channel
GC-3664 Voltage input, 16 bits 0~+5V 4-channel
GC-3674 Voltage input, 16 bits 0~+10V 4-channel
GC-3804 2-wire PT100, 16 bits Thermal resistance 4-channel
GC-3814 2-wire PT1000, 16 bits Thermal resistance 4-channel
GC-3822 3-wire PT100, 16 bits Thermal resistance 2-channel
GC-3832 3-wire PT1000, 16 bits Thermal resistance 2-channel
GC-3844 K type thermocouple Thermocouple 4-channel
GC-3854 S type thermocouple Thermocouple 4-channel
GC-3864 T type thermocouple Thermocouple 4-channel
GC-3874 J type thermocouple Thermocouple 4-channel
Analog output GC-4602 Voltage output, 16 bits -5V~+5V 2-channel
GC-4622 Voltage output, 16 bits -10V~+10V 2-channel
GC-4642 Current output, 16 bits 0-20mA 2-channel
GC-4652 Current output, 16 bits 4-20mA 2-channel
GC-4662 Voltage output, 16 bits 0~5V 2-channel
GC-4672 Voltage output, 16 bits 0~10V 2-channel
GC-4674 Voltage output, 12 bits 0~10V 4-channel
Special module GC-6101 RS232/RS485 extension
GC-6201 GPRS extension
GC-6501 WiFi extension
GC-8012 Power extension

v

Product Image






Related Products
GCAN-204 Converter Communication Device Connected To Canbus Plc
GCAN-204 Converter Communication Device Connected To Canbus Plc
US $ 185
GCAN-IO-8000 Standard CANopen Adapter PLC Slave Device IO Coupler Modular Design
GCAN-IO-8000 Standard CANopen Adapter PLC Slave Device IO Coupler Modular Design
US $ 129.9
GCAN-IO-8000 Standard CANopen Slave Station Modular Design
GCAN-IO-8000 Standard CANopen Slave Station Modular Design
US $ 129.9
Expandable GCAN-PLC Programming Controller China Manufacturer Original In Stock
Expandable GCAN-PLC Programming Controller China Manufacturer Original In Stock
US $ 259.9




Home  |  Product Catalog  |  News  |  Contact Us  |  Sitemap  |  Mobile Version

Powered by DIYTrade.com  Build your FREE website !
Find Best Price For China Products !